4 MPP trackers, 150% DC input oversizing Maximum PV input current: 20A, compatible with high power PV modules Maximum charge/discharge current: 200A, 150% EPS peak output power

IP66 protection degree DC & AC Type II SPD: prevents lightning damage Smart I‑V curve diagnosis function: accurately locates PV string faults and automatically detects faults

Support optional AFCI function EPS switching under 10 ms Support multi-inverters in parallel Support 100% unbalanced load Standard generator interface, supports generator and smart load access
| Technical Specifications | |
|---|---|
| Items | Description |
| INPUT (PV) | |
| Maximum PV Input Power | 48000Wp |
| Maximum PV Input Voltage | 1100V |
| Start Up Voltage | 2OOV |
| Rated Voltage | 620V |
| MPPT Voltage Range | 180V~1000V |
| Number of MPP Trackers | 4 |
| Number of Strings per MPPT | 2 |
| Maximum Current per MPPT | 40A |
| Maximum Short Circuit Current per MPPT | 60A |
| OUTPUT (ON GRID) | |
| Rated Output Power | 30kW |
| Maximum Output Power | 33kVA |
| Maximum Output Current | 50A |
| Maximum Input Power from Grid | 45kW |
| Maximum Input Current from Grid | 68.4A |
| Rated Grid Voltage | 3/N/PE,230V/400Vac |
| Rated Grid Frequency | 50Hz/60Hz |
| THDv(@Rated Power) | <3% |
| Power Factor | 0.8 leading ~ 0.8 logging |
| BATTERY | |
| Battery Type | Lithium |
| Battery Voltage Range | 300V-850V |
| Max Charge/Discharge Current | 44kW |
| Max Charge/Discharge Current | 2*100A |
| Communication | CAN/RS485 |
| OUTPUT (EPS) | |
| Rated Output Power | 30kW |
| Maximum Output Current | 45.6A |
| Peak Output Power, Time | 1.5 times/10s |
| Switch Time | <10ms |
| Rated Voltage | 3/N/PE,230V/400Vac |
| Rated Frequency | 50Hz/60Hz |
| Maximum AC passthrough current | 150A |
| OUTPUT (GENERATOR) | |
| Maximum Output Power | 30kW |
| Maximum Output Current | 45.6A |
| Rated Voltage | 3/N/PE,230V/400Vac |
| Rated Frequency | 50Hz/60Hz |
| EFFICIENCY | |
| Maximum Efficiency | 98.40% |
| European Efficiency | 97.50% |
| Battery Charge /Discharge Efficiency | 97.50% |
| PROTECTION | |
| Protection | DC Switch, DC Reverse, Polarity Protection, Anti-Islanding Protection, AC Short Circuit Protection, Residual Current Monitoring, Ground Fault Monitoring, Over Current /Voltage Protection, Battery Active Function, I-V Curve Scan |
| Surge Protection | Type II |
| AFCI Protection | Optional |
| GENERAL DATA | |
| Display | LCD/LED |
| Weight | 92kg |
| Dimension (W*H*D) | 620*900*300mm |
| Operating Temperature Range | -30°C~+60°C |
| Cooling Method | Smart Cooling |
| Protection Degree | IP66 |
| Maximum Operating Altitude | 400m |
| Relative Humidity | 0~100% |
| Self Consumption | <15W |
| Topology | Transformerless |